Pic.20 MegaMacs system on a job site during operations
6.4. Centrifuge safety
As a result of high speed centrifuge might vibrate during
operations. This might result in wearing of main supporting
bearings. To prevent such event system constantly monitors vibration
and bearings temperature. Ones one of this parameters reach the
limit system shuts down automatically.
7. МегаМАКС technical
specification
Production
capacity extracting bottom sludge of petroleum products:
- Using Robotic Canon
- Using Extractor
|
Up to 7,0 м 3/hr
Up to 15 м 3/hr
|
Main unit diesel engine fuel consumption (Caterpillar
C13)
|
18 liters/hour
|
Centrifuge unit diesel engine fuel consumption
(Caterpillar C9)
|
14 liters/hour
|
Heat Exchanger fuel consumption (diesel) *
|
80 – 120 liters/hour
|
Volume of cleaning/diluting agent being in recirculation
|
37,85 м3
|
Hydraulic fluid volume
|
1,022 liters
|
Fuel tanks capacity in both MegaMacs and Centrifuge
units.
|